5.4 Release Notes
5.4.4.4
- Improvement: Added an option to auto-create Primary/Secondary Layers from imported DXF reference split-colours
- Improvement: Made Convert Centrelines inherit Primary/Secondary Layers from reference graphic
- Improvement: Added a shortcut to the Spreadsheet tool from the Activity Track window
- Improvement: Added Activity Track heat to Heat| New Heat Input and Heat | Diesel Power properties
- Improvement: Added buttons to quickly filter spreadsheet by fan or by resistance
- Improvement: Added Unit Settings and Spreadsheet Saved Views to Inherit tool
- Improvement: Stopped Spreadsheet Saved Views saving automatically, now requires a click on the save button.
- Improvement: Added a field to enter a Refuge Bay name
- Bug fix: Made Spreadsheet Saved Views retain all filtering and grouping options
- Bug fix: fixed orientation arrows position when using the View | Copy HiRes tool
- Bug fix: made Utilisation Factor backwards-compatible to older versions of Ventsim
- Bug fix: fix for Stage popup occasionally not saving properly
5.4.4.3
- Improvement: Made Clip Level single click expand to entire level and update the data manager
- Improvement: Added layer name to layers created with the Split by Colour option
- Bug fix: removed report of StageLock results when stage is locked and relocked automatically
- Bug fix: fixed Import DXF Split By Colour option work for subsequent imports
- Bug fix: stopped airway shape change when using Duct Delete button
- Bug fix: corrected Primary Layers merging during File | Merge
- Bug fix: stopped changes to airway shape affecting airway size on Edit Box
5.4.4.2
- Improvement: Allowed Secondary fans to be considered in series for Recommend Fan
- Improvement: Added readonly Z coordinate relative to sea level to Info tab of Edit Box
- Improvement: Added Size Adjustment feature to scale an airway size to match the surveyed Ventlog area
- Improvement: Better user control of Activity Track starting point and preferred direction at junctions
- Bug fix: Fixed maintenance date calculation
- Bug fix: Labels on Activity Track form
- Bug fix: Fixed bug on path determination on branching Activity Tracks
- Bug fix: Fixed Imperial unit conversion error on Fan Installation Resistance form
5.4.4.1
- Improvement: Added Size Area comparison for Ventlog
- Improvement: Added button to Fire Tab of Edit Box to open Dynamic Graph
- Bug fix: Made close of Edit Box also clear airway selection
- Bug fix: Fixed problem when loading larges reference graphics through the Inherit tool
- Bug fix: Corrected counting of heat sources from Activity Tracks on the Summary form
- Bug fix: Stopped perimeter incorrectly updating on change of area on Irregular shape airways
- Bug fix: Fixed load of spreadsheet view on the Fire Events Manager
- Bug fix: Cleared out empty Presets from the Activity Track form
- Bug fix: Automatically turned off Jet Fan option on airways with no fan
- Bug fix: Improved behaviour of changes to Gradient field in the Edit Box
5.4.4.0
- Improvement: Addition of a Convert To Overpass tool
- Improvement: Made Caving Air Blast connections always point away from cave
- Bug fix: fixed reference graphic stage selections when deleting stages
- Bug fix: made new ducts take default temperatures, not parent temperatures
5.4.3.9
- Improvement: Added tool to export all dynamic monitor data
- Improvement: Adding a message box or data box, turns on visibility, if off
- Improvement: Excluded piston effect pressure from Boost TP property, new property for piston effect
- Improvement: Added to group entry feature to Ventlog Add Records from Ventsim
- Improvement: Made staged Message Box visible if the airway(s) it is attached to is unstaged
- Bug fix: fixed determination of some license maintenance dates
- Bug fix: Removed bug where airway at index 0 could not be added to Activity Track
- Bug fix: Howden Fan tool, removed unused fan names, changed labels
5.4.3.8
- Improvement: Added the Howden Fan Lookup tool
- Improvement: Added Tunnel type to Advanced Find & Select
- Improvement: Added Airway Profile as a colour property
- Improvement: Added some default Spreadsheet configurations
- Improvement: Added graph export and camera buttons to the Caving Air Blast Simulation form
- Bug fix: Stopped fan guids and Primary/Secondary option changing on cancel of fan database edits
- Bug fix: Improved error message when Recommend Fan is attempted on a restricting Fixed Flow
- Bug fix: Improved calculation of perimeter on round airways with obstruction or backfill
- Bug fix: Catch for possible loading bug with the ShowAll option
- Bug fix: Better handling of Recommend Airway Size tool when used on airways with Tunnel Type presets
5.4.3.7
- Bug fix: Added fix for graphics lag with large models and large Track airway count
5.4.3.6
- Improvement: Made switching Tunnel type apply all tunnel property changes straight away
- Improvement: Howden Recommend Fan, now imports the maximum power
- Improvement: Made warnings, such as Fan Motor Power Exceeded clear straight away, when resolved
- Improvement: Added setting option for Escape Route calculations to be performed using Russian standard calculation
- Improvement: Made Dynamic Message Box “Show All” options carry over in detached stage creation
- Bug fix: corrected Profile builder copy-paste for all languages
- Bug fix: replaced Recommend Size button for Diameter property on Edit Box
- Bug fix: fixed possible track simulation failure after continuing Fire Simulation after Escape Route calculation
- Bug fix: corrected error in interaction of Undo and new track graphics
- Bug fix: added horizontal airway friction and duct losses to Energy Summary, corrected Shock Loss summation
- Bug fix: fixed Edit Box Stage selection tool
- Bug fix: fixed load of Ventlog compare tool for stations without a mapping to an airway
- Bug fix: fixed bug with Stage popup tool that allowed first stage to sometimes be automatically selected
5.4.3.5
- Improvement: Added Ventsim humidity comparisons as airway property
- Improvement: Allowed user control of airway shape rotation
- Improvement: Added total Duct Heat Transfer output to the Construct Duct Form
- Bug fix: Fixed slowness when using Build Ramp
- Bug fix: Fixed issue with graphing tools in the Duct form
- Bug fix: Fixed issue where No Thoroughfare could not be changed after dynamic simulation restore.
5.4.3.4
- Improvement: Added toggle for different layouts of the Visibility Manager
- Improvement: Added a Remove Selection button to Message Box Editor. Improved stage handling for airways
- Improvement: Added option to switch whether Edit Box updates on changed selection
- Improvement: Made un-excluding an airway set off the Heat Sim out of date warning
- Improvement: Made Light On button on Reference Manager turn on the global Reference Visibility toggle
- Improvement: Added option to set an automatic shock loss to fans when installed underground
- Improvement: Added a Fan Losses output to the Fan Info Box
- Improvement: Added a tool to graph the variation of parameters across stages, on individual airways
- Improvement: Made Message Box Inherit option to search for corresponding airways
- Bug fix: fixed crash with interaction of Piston Effect and Annual Thermal Flywheel
- Bug fix: various fixes for new arrows graphic
- Bug fix: fixed power output for low pressure fans with different length pressure and power curves
- Bug fix: corrected row spacing on Fan tab of the Edit Box
- Bug fix: made Profile Draw Tool update on edit of grid values
- Bug fix: fix for history view of Ventlog records where single reading could be split into separate rows
5.4.3.3
- Improvement: Added configurable Maximum Icon Size
- Improvement: Added a Utilisation Factor to the Heat Moisture Diesel Presets
- Improvement: Added Cost output to Coolers, standard and flywheel simulations
- Improvement: Made Graphs refresh on Dynamic Simulation Pause, and made Path Graphs old after simulation
- Improvement: Added conveyor and waterway heat to path graphs
- Improvement: Made Activity Track offsets in the graphics better for models with many Tracks
- Improvement: Made a lower upper limit for Heat Simulation Accuracy of 0.1 degrees Celsius
- Improvement: Made double-click with Move and Duplicate tools on Message Boxes open the Editor
- Improvement: Made the Stage selection dropdown menu wider
- Improvement: Added Unique Number and Airway Name to export of Path Graph data
- Improvement: Added option to add an orientation axis to bottom right of viewer
- Bug fix: Stopped Fix Flow icon deletion wiping the fixed flow value
- Bug fix: Fixed out of shape Fan Graph on old Edit Box
- Bug fix: Fixed occasional display of incorrect density on airways during Dynamic Simulation
- Bug fix: Fixed Fixed Heat Cooling Icon colour
- Bug fix: Fix for LiveView import of .csv files
- Bug fix: Made Track editor work when switching Stages and switching Show Staged Tracks option
5.4.3.2
- Bug fix: fix for some Edit Box fields not saving properly after Heat Preset change
5.4.3.1
- Improvement: Stopped flashing airways triggering full graphics update
- Improvement: Improved speed of Calculate VRT Tool
- Improvement: Added separate Strict Modes, one for Friction Factor and one for Fixed Flows
- Improvement: Added Message Boxes to the Inherit function
- Improvement: Added a property, Attributes | Parallel Airways
- Bug fix: Fixed Equivalent Orifice property
- Bug fix: Fixed issue where changing tunnel type dirtied the resistance type, for multiple airways
- Bug fix: Fixed UI unit conversion problem in the Edit form
- Bug fix: Fixed problem with messages and tracks when merging file of multiple stages
5.4.3.0
- Improvement: Updated translations
- Improvement: Added a regulator resistance property
- Improvement: Improved graphics performance when airways flashing
- Bug fix: Fixed Air Simulation error when running MultiSim and incompressible flows
5.4.2.9
- Improvement: Made addition of node to conveyor or waterway related airway not break the conveyor/waterway
- Improvement: Fixed Edit Box to show roughness when using a Friction Factor Preset with Roughness
- Improvement: Made image drag and drop ignore the Reference Lock
- Improvement: Made texture appear immediately after Adding from the Data Manager
- Improvement: Added Elevation Relative to Sea Level and Surface Datum properties to Descriptors
- Improvement: Included conveyors and waterways on Heat Summary graphs
- Bug fix: Made Size setting on Message Boxes set relative message box size
- Bug fix: Fixed save of Cooler Discharge Temperature setting
- Bug fix: Added a constant non-surface base pressure when running Caving Air Blast Simulation
- Bug fix: Fixed Convert Floorlines method
5.4.2.8
- Improvement: New Stage Control on Track, Message Box and Reference Editors
- Improvement: Ventlog mapping now limited to current stage
- Improvement: Added links to Ventsim webinars
- Improvement: Made copied ducts, waterways and conveyors copy to new groups
- Improvement: Made Reference and Texture Move tools ignore the Reference Lock
- Improvement: Added an Elevation Above Sea Level Property
- Improvement: Improved Matrix solver convergence for extremely low air densities
- Bug fix: Fix for track loading in Editor
- Bug fix: Added a catch for impossible FOM calculation in Heat Calculator
- Bug fix: Fixed Wetness Fraction Preset button on Edit form
- Bug fix: Improved Edit Box UI controls of Heaters and Coolers
- Bug fix: Force resistance recalculation after change to Obstruction field in Edit form
- Bug fix: Fixed Presets form select for Custom Profiles
- Bug fix: Corrected reset of Fan Edit control which was sometimes hiding rows
- Bug fix: Fixed problem with Save Check when closing Ventsim with Stage Locked
5.4.2.7
- Improvement: Added a Cooler feature
- Improvement: Added Duct Heat Transfer properties, including to graphs
- Improvement: Added some more default Duct Heat Transfer Presets
- Improvement: Added maximum CO to Escape Route information
- Improvement: Added option to Caving Air Blast Simulation for seals either to fail or to only warn of failure
- Improvement: Added buttons to generate graphs on the Construct Duct, Construct Waterway and Construct Conveyor forms
- Improvement: Activity Track Editor, improved stage tooltips and made stage automatically activate on addition of airways
- Improvement: Added a contaminant mass portion property, showing the percentage of original contaminant mass present in an airway
- Improvement: Made airways invisible in Solid Mode (e.g. Duct Leakage) nonetheless selectable when they would otherwise have been visible in WireFrame mode
- Bug fix: fix for duct heat transfer not completing on simple models.
- Bug fix: corrected shape saving on Construct Duct for custom shapes using Area-Perimeter
- Bug fix: fixed problem where icon movement was being incorrectly prohibited
- Bug fix: fix for LiveView sensor reading when no sensor type has been allocated
- Bug fix: Correction to coordinate edit in Edit Box for multiple airways
- Bug fix: Forced Air Simulation before use of Recommend Regulator and Orifice
5.4.2.6
- Improvement: Added minimum velocity option to Tunnel Type Preset
- Improvement: Greatly improved the speed of Convert Centrelines in large models
- Improvement: Added option to select different Profile shapes in the Duct Builder
- Improvement: More UI output for Caving Air Blast Simulation
- Bug fix: Fixed error that occurred when Caving Air Blast was run with only one connection.
- Bug fix: Fixed bug where some dynamic data saved with file could be lost
- Bug fix: Fixed error where Duct Leakage could be lost with Delete Outside of Fence
- Bug fix: Correction for problem where number format culture was defaulting to UI language culture
- Bug fix: Fixed problem where Heat icon sometimes appeared next to Fire icon
- Bug fix: Escape routes, made visibility limit consistent across graphs
5.4.2.5
- Improvement: Update to Ventsim Manual 5.4 Spanish
- Improvement: Added piston effect pressure total to Track Editor and path graph
- Improvement: Removed changing of cursor with Advanced Find & Select
- Bug fix: Forced graphic shape update on Stage change
- Bug fix: Included save of the Overpass user Settings
5.4.2.4
- Improvement: Addition of link in Help menu to Ventsim Webinars
- Improvement: Added the ability to edit a Ventlog Station from Ventsim
- Improvement: Added fixed temperature heating and refrigeration information to Heat Summary
- Improvement: Updated translations
- Bug fix: fixed incorrect image on Edit form simulation button for Dust
- Bug fix: fixed tool for clearing Custom Icons
- Bug fix: fix for Heat sources in ducts during Dynamic Simulation
- Bug fix: Fixed backwards compatibility for fixed temperatures in heat events
5.4.2.3
- Improvement: Addition of icon, progress window, configurable settings and graph for the Caving Air Blast Simulation
- Bug fix: Issue with Fix Temperatures turning on on Heat Event form
- Bug fix: Correction to NVP and Shock pressure losses reporting to the Edit form Info tab
5.4.2.2
- Improvement: Allowed up to 32 Stages to be used
- Improvement: Further improvements to Parallel Fan Stall Predictor
- Improvement: Improved System R and Peak capacity fan output info for single and combined fan graphs
- Improvement: Allowed 0 degrees fixed temperatures to be set
- Bug fix: fixed bug with Rock preset for Conveyors
- Bug fix: fixed bug where Regulator points sometimes could not be saved
- Bug fix: fixed some problems around unique airways being wrongly identified on Stage unlock
5.4.2.1
- Improvement: Added Activity Track Duplicate button on Track Editor
- Improvement: Added button to Track Editor to search for airways on current stage that correspond to airways on the track on other stages
- Improvement: Added a Remove Selection button to Track Editor
- Improvement: Made extension of existing Tracks to new stages optional
- Improvement: Added option to only show staged Tracks
- Improvement: Made copy to clipboard message temporary
- Improvement: Excluded excluded airways from some warning messages
- Improvement: Added Fog to available thermal flywheel results
- Improvement: Improvements to Fan Interaction Stall Predictor, including single fans in parallel in separate airways
- Improvement: Allowed blank input of model title
- Improvement: Added Contaminant Mass property
- Improvement: Added property Energy: Fan Shaft Power
- Bug fix: Added prompts to file save from Track Editor
- Bug fix: Corrected Restore Defaults
- Bug fix: Forced Heat Sim to occur on stage change when option selected
- Bug fix: Fix for Ventlog stations with no data values
- Bug fix: Corrected default name of detached Stage
- Bug fix: Fixed save of Rock Ages for multiple airways
- Bug fix: Fixed diesel emission for vehicles per length option on Activity Tracks
- Bug fix: Fixed muckpile resistance calculation for Caving Blast Simulation
5.4.2.0
- Improvement: Added new Fan Interaction Stall Predictor tool
- Improvement: Added ability to view Activity Tracks from Heat tab of the Edit Form
- Improvement: Added Pass/Fail to audit report Word export
- Improvement: Updated translations for Spanish, Russian and Chinese
- Improvement: Added Radon to goal seek tool and fixed progeny setting
- Improvement: Now saves option to always reset network after dynamic sim
- Improvement: Simplified Annual Flywheel settings
- Improvement: Background colour for references listed in Data Manager now matches the colour of the reference
- Bug fix: Fix for minimum temperature being overridden by lower regular temperatures in Annual Flywheel
- Bug fix: Fix for when adding fans from the Fan Select tool so that fans with the same name are grouped together instead of replaced
- Bug fix: Fix for Static Scripting tool
- Bug fix: Fix for issue when rendering text offset from icon position when the text size is too small
5.4.1.9
- Improvement: Searchable drop-down menu in the Advanced Find Select
- Improvement: Added a refresh to Advanced Message Boxes every 2 seconds during Dynamic Simulation
- Bug fix: Fixed to make LiveView refresh sensor data according to the set refresh interval
- Bug fix: Fixed Gas Injection and Linear Emission to work with Dynamic Simulation when using large relative injection amounts
- Bug fix: Added a catch for crash in Edit Box when no Regulators are available in Presets.
5.4.1.8
- Improvement: Made Conveyors and Waterways ignore source temperatures connected upstream
- Improvement: New Tool to reset text positions on airways
- Improvement: Added a Fixed Flow category to Advanced Find and Select
- Bug fix: Fixed dust sensors in Dynamic simulation
- Bug fix: Fix for horizontal round airways in Airway Optimizer
- Bug fix: Corrected unit conversions on display of Shock Equivalent Length in Edit Box
- Bug fix: Fixed Gas check boxes to allow specification of unfixed gas concentrations in Edit Box
5.4.1.7
- Improvement: Adjusted data placement for inlet/outlet values, added Text Settings to toggle effect and adjust
- Improvement: Made Summary Form for Activity Tracks limit to selected airways and only show staged Activity Tracks
- Improvement: Added Fixed Temperature refrigeration to summary tabs Graphs and Energy
- Improvement: Added warning on new Edit Box when saving a Fan or Fix edit on multiple airways
- Bug fix: Fixed loading of Message text with special characters
- Bug fix: Scroll wheel on Scale Manager fixed, now always updates, regardless of model size
- Bug fix: Added text refreshes after moving airways and moving or adding icons
- Bug fix: Stopped reload of Advanced Find and Select when not visible
- Bug fix: Fixed slow to run Convert Centrelines
- Bug fix: Fixed PQ survey for Advanced Find Select, added reload when opening
- Bug fix: Forced Heat Active when using heat Presets, fixed bug when deleting heat presets from multiple airways
- Bug fix: Fixed Dynamic Messages for negative values
- Bug fix: Removed extra tab indent that was appearing in message boxes
- Bug fix: Fix for importing dust sensor values when running dynamic sensor or dynamic script simulations
5.4.1.6
- Improvement: Increased maximum allowable resolution of imported textures to 2K
- Improvement: Made Activity Track and Message Box airway selections respond correctly to addition of detached stage
- Improvement: Added additional checks to remove existing airways, tracks and messages from blank and detached stages
- Bug fix: fixed Waterway toggle affecting Conveyor Heat
- Bug fix: made a catch in Heat Simulation when encountering multiple fixed zero length Duct
- Bug fix: fixed link to Reset Default Presets for Combustion fuels
- Bug fix: made Activity Track stage selection react correctly to Stage reordering
- Bug fix: fixed Activity Track form layout
5.4.1.5
- Improvement: Limited Distance to surface and refuge calculation to current stage
- Improvement: Forced update of Advanced Find and Select after icon deletion, moving and duplicating
- Improvement: Added warning for deletion of Presets used on Activity Tracks
- Improvement: Made it so leakage paths are always added with ducts
- Bug fix: Made fix for invalid Favourites setting
- Bug fix: Fix for creation of multiple windows
- Bug fix: Made Gas properties always available in colours
- Bug fix: Added catch for Data Entry errors in Activity Track grid
5.4.1.4
- Improvement: Made count of Heat and Vehicle in use on Presets form include use on Activity Tracks
- Improvement: Made messages jump to first unread message
- Improvement: Added Gas/Contaminant/Dust Injection option, steady and dynamic
- Improvement: Prevented Conveyor and Waterway temperatures automatically resetting
- Improvement: Added PQ Survey and Airway Notes icons to Visibility Manager
- Bug fix: Fixed Recirculation Simulation to limit to only current stage, improved Cancel button responsiveness
- Bug fix: Made Fire Wizard handle fuel with zero density specified
- Bug fix: Fixed operation of No Thoroughfare option on surface-connected airways
- Bug fix: Disable Stage changing and editing while simulation running
- Bug fix: Made Advanced Find and Select work for Data Boxes
5.4.1.3
- Improvement: Updated demonstration model
- Improvement: If duplicating a group of airways, put new airways in a new group
- Improvement: Edit Box updates after use of Invert Selection
- Improvement: Fixed Temperature icon becomes blue if cooling
- Improvement: Made Modify Duct save to the Undo loop
- Improvement: Made Overpass builder ignore the Intersection Lock Setting
- Improvement: Made Heat Calculator Accept button always update Edit Box, if available
- Improvement: Clearer user interface around Rock Age on the Edit Box
- Bug fix: Fixed UI update of Rock Date Mined when entering a year (eg. 2005) in the Rock Age field
- Bug fix: Corrected calculation of variable mass flow rates in Conveyor builder
- Bug fix: Made perspective toggle update text
- Bug fix: Fixed missing stage on creation of Message Box on first stage
- Bug fix: Made dimensions update on change of shape in old Edit Box
5.4.1.2
- Improvement: Added a button to Filter form to reset to installation settings
- Improvement: Heaters, added moisture from fuel combustion to the heat added by the heater
- Bug Fix: Corrected humidity correction when using fixed dry bulb and floating wet bub temperatures
- Bug Fix: Fixed saving of Primary/Secondary Option on Fan Editor
- Bug Fix: Fixed Export to Word from Audit Tool
- Bug Fix: Corrected input of Gas Linear Emission on new Edit Box
- Bug Fix: Made text refresh when Relative Text option is toggled via Settings
- Bug Fix: Made reference text refresh when Reference Layer visibility is changed
- Bug Fix: Made fixed temperatures work in Dynamic Simulation, when either dry or wet bulb is not specified
- Bug Fix: Fixed loss of Unit Settings when using the Inherit Tool
- Bug Fix: Allowed for smaller fan charts in old Edit Box
5.4.1.1
- Improvement: Added Heater information to the Annual Thermal Flywheel
- Bug Fix: Prevented Stage list growing with blank stage name
5.4.1.0
- Improvement: Fix for calculation of oval perimeter in Duct Calculator
- Improvement: Updated translations for Spanish and Russian
5.4.0.9
- New Feature: Language options in stand-alone Duct Calculator installer.
- New Feature: Added option to take a snapshot of Duct Calculator
- Improvement: Updated translations
- Improvement: Heat Simulation, made fixed temperature setting treat air moisture more realistically for cooling and heating scenarios
- Fix for problem with saving of spreadsheet view
- Fixed Estimate Fan Static Pressure Curve tool to use fan density, not standard density
- Fixed potential crash in some Heat Calculator options with non-numerical inputs
- Fixed potential incorrect Heat Added result reported in final month of airway flywheel graph results
- Fixed issues that could occur when using both LiveView and Dynamic Scripts in the same model
5.4.0.8
- New Feature: Text rendering engine allowing for text borders for improved readability and text displayed while rotating.
- New Feature: Heaters now configurable on the Heat tab
- Improvement: Fixed Flow (Fan) and Fixed Flow (Regulator) categories in Advanced Find & Select
- Improvement: Addition of a new Safety category to the properties
- Improvement: Duct Calculator graph improvements; addition of Fan Curve graph.
- Fix for loading models saved in excel file format
- Fix for issue that could occur when saving non-advanced message boxes
- Fix for backup files saving with special characters in the name
- Fix for efficient saving of Fan images
5.4.0.7
- Fixed Multi Windows not being able to leave the main form
- Fix for when multi windows could crash if first window was closed before making a new one
- Fix for Translations in Duct Calculator
- Fix for resistance icons not showing
- Fixed monitor graph not loading on the previously open data type
5.4.0.6
- New Feature: Add custom icons for Regulators
- Improvement to VentFire scripting to allow transitions curve of less than 1m
- Fix for importing live view sensors where multiple sensors are on one row
- Fix to allow live view update to refresh comments as well as data values direct from the source
- Change to dynamic messages to update less frequently
- Fix for Escape key to un-select message boxes
- Added Gradient as an attribute for airway text
- Fix for some situations where Rock Preset Temp had deviated from Environment settings
- Fix for Airway Diameter showing the effective diameter on circular airways instead of the full diameter
- Fix for cases where Perimeter could be calculated incorrectly when changing shape and dimensions in the same edit
- Adjusted Duct Calculator label sizes to better accommodate Spanish
- Updated Manual for 5.4